The weighing industry continues its relentless march towards perfection. Leading this parade is the AL150W load cell by HOLI Scale, an embodiment of precision coupled with robust design.
Precision That Speaks Volumes
The AL150W doesn’t just meet industry standards; it sets them. With its incredible accuracy, it ensures that every weighing is as precise as the last, making it a jewel in the crown of high-fidelity load cells.
Sturdy, Yet Spacious
Where the AL150W truly differentiates itself is its widened design. While maintaining the ability to handle impressive loads up to 500kg, it offers a broader base, ensuring stability and flexibility for a myriad of weighing applications.
Crafted in Superior Aluminium
The choice of aluminium is no accident. Renowned for its strength and durability, it mirrors the commitment of HOLI Scale to create products that are not just efficient but enduring. With the AL150W, expect a load cell that will stand the test of time and rigorous usage.
Adaptable Across Industries
The AL150W is designed keeping in mind the diverse needs of different sectors. From the rigorous demands of industrial setups to the precision needs of research labs, it caters with unmatched consistency.
Conclusion
With the AL150W, HOLI Scale has once again demonstrated why they are industry leaders. Merging precision with a robust design and presenting it in a widened format, the AL150W is not just a product but a promise of reliability and efficiency.
Specifications | |||||||
Parameter | Value | Units | |||||
Rated capacity (Emax) | 30 / 50 / 60 / 100 / 150 / 200 / 250 / 300 / 500 | kg | |||||
Accuracy class | C3 | C3MR | C5 | C6 | |||
Maximum number of LC intervals (nmax) | 3000 | 2*3000 | 5000 | 6000 | |||
Min. LC verification interval (vmin) | Emax/5000 | Emax/10000 | g | ||||
Temp. effect on zero balance | ± 0.0028 | ± 0.0014 | % of Emax/℃ | ||||
Zero balance | ± 0.1 | mV/V | |||||
Rated output | 2.0 | mV/V | |||||
Rated output tolerance | ± 0.2 | mV/V | |||||
Temp. effect on rated output +20…+40℃ | ± 0.00175 | ± 0.00175 | ± 0.00105 | ± 0.00087 | % of AL/℃ | ||
-10…+20℃ | ± 0.00117 | ± 0.00117 | ± 0.0007 | ± 0.00058 | |||
Hysteresis error | ± 0.0175 | ± 0.0175 | ± 0.0105 | ± 0.0105 | % of Emax | ||
Non-linearity error | ± 0.0175 | ± 0.0175 | ± 0.0105 | ± 0.0105 | % of Emax | ||
Min. dead load output return | ± 0.0166 | ± 0.0166 | ± 0.0100 | ± 0.0083 | % of AL | ||
Offer center load error(OIML R76) | ± 0.0044 | ± 0.0044 | ± 0.0026 | ± 0.0022 | % of AL/cm | ||
Terminal resistance | Excitation | 404 ± 15 | Ω | ||||
Output | 350 ± 3 | Ω | |||||
Insulation resistance @50VDC | >2000 | MΩ | |||||
Excitation voltage | Recommended | 10 | V AC/DC | ||||
Maximum | 15 | V AC/DC | |||||
Temperature range | Compensated | -10 to +40 | ℃ | ||||
Operating | -10 to +50 | ℃ | |||||
Safe storage | -25 to +70 | ℃ | |||||
Load limit | Safe | 150 | % of Emax | ||||
Ultimate | 300 | % of Emax | |||||
Protection | Type | Silicone rubber over gage | |||||
IP rating | IP65 | ||||||
OIML / European Approval | OIML Cert. No. | R60-2017-A-NL1-22.22 | |||||
European Cert. No. | TC11564 | ||||||
Class | C6 | ||||||
nmax | 6000 | ||||||
NTEP Approval | Cert. No. | 23-027 | |||||
Class | III | ||||||
nmax | 6000 | ||||||
Cable | Length | 1.5 | m | ||||
Type | 4-wire, PVC | ||||||
Diameter | Φ5 | ||||||
Construction | Aluminum | ||||||
Maximum platform size | 400 x 500 | mm | |||||
Recommended torque | 14.0 | N.m | |||||
Notes: The values for linearity, hysteresis and temp. effect on rated output are recommended values, the sum of these data meets the requirements according to OIML R60. |
The weighing industry continues its relentless march towards perfection. Leading this parade is the AL150W load cell by HOLI Scale, an embodiment of precision coupled with robust design.
Precision That Speaks Volumes
The AL150W doesn’t just meet industry standards; it sets them. With its incredible accuracy, it ensures that every weighing is as precise as the last, making it a jewel in the crown of high-fidelity load cells.
Sturdy, Yet Spacious
Where the AL150W truly differentiates itself is its widened design. While maintaining the ability to handle impressive loads up to 500kg, it offers a broader base, ensuring stability and flexibility for a myriad of weighing applications.
Crafted in Superior Aluminium
The choice of aluminium is no accident. Renowned for its strength and durability, it mirrors the commitment of HOLI Scale to create products that are not just efficient but enduring. With the AL150W, expect a load cell that will stand the test of time and rigorous usage.
Adaptable Across Industries
The AL150W is designed keeping in mind the diverse needs of different sectors. From the rigorous demands of industrial setups to the precision needs of research labs, it caters with unmatched consistency.
Conclusion
With the AL150W, HOLI Scale has once again demonstrated why they are industry leaders. Merging precision with a robust design and presenting it in a widened format, the AL150W is not just a product but a promise of reliability and efficiency.
Specifications | |||||||
Parameter | Value | Units | |||||
Rated capacity (Emax) | 30 / 50 / 60 / 100 / 150 / 200 / 250 / 300 / 500 | kg | |||||
Accuracy class | C3 | C3MR | C5 | C6 | |||
Maximum number of LC intervals (nmax) | 3000 | 2*3000 | 5000 | 6000 | |||
Min. LC verification interval (vmin) | Emax/5000 | Emax/10000 | g | ||||
Temp. effect on zero balance | ± 0.0028 | ± 0.0014 | % of Emax/℃ | ||||
Zero balance | ± 0.1 | mV/V | |||||
Rated output | 2.0 | mV/V | |||||
Rated output tolerance | ± 0.2 | mV/V | |||||
Temp. effect on rated output +20…+40℃ | ± 0.00175 | ± 0.00175 | ± 0.00105 | ± 0.00087 | % of AL/℃ | ||
-10…+20℃ | ± 0.00117 | ± 0.00117 | ± 0.0007 | ± 0.00058 | |||
Hysteresis error | ± 0.0175 | ± 0.0175 | ± 0.0105 | ± 0.0105 | % of Emax | ||
Non-linearity error | ± 0.0175 | ± 0.0175 | ± 0.0105 | ± 0.0105 | % of Emax | ||
Min. dead load output return | ± 0.0166 | ± 0.0166 | ± 0.0100 | ± 0.0083 | % of AL | ||
Offer center load error(OIML R76) | ± 0.0044 | ± 0.0044 | ± 0.0026 | ± 0.0022 | % of AL/cm | ||
Terminal resistance | Excitation | 404 ± 15 | Ω | ||||
Output | 350 ± 3 | Ω | |||||
Insulation resistance @50VDC | >2000 | MΩ | |||||
Excitation voltage | Recommended | 10 | V AC/DC | ||||
Maximum | 15 | V AC/DC | |||||
Temperature range | Compensated | -10 to +40 | ℃ | ||||
Operating | -10 to +50 | ℃ | |||||
Safe storage | -25 to +70 | ℃ | |||||
Load limit | Safe | 150 | % of Emax | ||||
Ultimate | 300 | % of Emax | |||||
Protection | Type | Silicone rubber over gage | |||||
IP rating | IP65 | ||||||
OIML / European Approval | OIML Cert. No. | R60-2017-A-NL1-22.22 | |||||
European Cert. No. | TC11564 | ||||||
Class | C6 | ||||||
nmax | 6000 | ||||||
NTEP Approval | Cert. No. | 23-027 | |||||
Class | III | ||||||
nmax | 6000 | ||||||
Cable | Length | 1.5 | m | ||||
Type | 4-wire, PVC | ||||||
Diameter | Φ5 | ||||||
Construction | Aluminum | ||||||
Maximum platform size | 400 x 500 | mm | |||||
Recommended torque | 14.0 | N.m | |||||
Notes: The values for linearity, hysteresis and temp. effect on rated output are recommended values, the sum of these data meets the requirements according to OIML R60. |