Product Description:
Capacity:50kg to 1000kg
The HL6G load cellfrom HOLI Scale is a high-precision, single point load cell. In the realm of high-precision weighing, there's a new benchmark in town: the HOLI Scale's HL6G load cell. As industries evolve and the demand for accurate measurement solutions intensifies, the HL6G emerges as a cutting-edge instrument designed to elevate weighing processes to new heights.
It meets Precision C3 standards, meaning it gives you consistent results with great accuracy. Its design makes it perfect for platform scales and other scale parts where performance matters. Whether used in shops, factories or labs, this single point load cell offers dependable weighing power you can trust.
Key Features:
Built from anodized aluminium alloy steel for lasting durability
Precision C3 rating for high-accuracy readings
Fits well into many types of scale parts and platforms
Compact and easy to mount single point load cell
Ideal for everyday use in weighing systems
The HL6G offers great value and performance – perfect for those who need a high-quality load cell for daily weighing needs.
Model | Products Description |
HL6G-200kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
HL6G-300kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
HL6G-500kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
HL6G-750kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
Qualification | ||
Load Rating | Kg | 200/ 300/ 500/ 750 |
Precision | C3 | |
Maximum Division | Nmax | 3000 |
Minimum Division | Vmin | Emax/7000 |
Composition Error | (%FS) | ≤±0.020 |
Creep Deformation | (%FS/30min) | ≤±0.0167 |
The influence of temperature on the output sensitivity | (%FS/10℃) | ≤±0.0175 |
The influence of temperature on the zero output | (%FS/10℃) | ≤±0.020 |
Rated Output | (MV/V) | 2.0±0.2 |
Input impedance | (Ω) | 406±6/1065±15 |
Output impedance | (Ω) | 350±3/ 1000±10 |
Insulation Resistance | (MΩ) | ≥5000(50VDC) |
Zero output | (%FS) | 2 |
Temperature compensation range | (℃) | -10~+40 |
Working temperature range | (℃) | -35~+65 |
Recommend excitation voltage | (V) | 5~12(DC) |
Maximum excitation voltage | (V) | 18(DC) |
Safety overload range | (%FS) | 150 |
Limit overload range | (%FS) | 300 |
Position Error | 0.02%/100mm |
Product Description:
Capacity:50kg to 1000kg
The HL6G load cellfrom HOLI Scale is a high-precision, single point load cell. In the realm of high-precision weighing, there's a new benchmark in town: the HOLI Scale's HL6G load cell. As industries evolve and the demand for accurate measurement solutions intensifies, the HL6G emerges as a cutting-edge instrument designed to elevate weighing processes to new heights.
It meets Precision C3 standards, meaning it gives you consistent results with great accuracy. Its design makes it perfect for platform scales and other scale parts where performance matters. Whether used in shops, factories or labs, this single point load cell offers dependable weighing power you can trust.
Key Features:
Built from anodized aluminium alloy steel for lasting durability
Precision C3 rating for high-accuracy readings
Fits well into many types of scale parts and platforms
Compact and easy to mount single point load cell
Ideal for everyday use in weighing systems
The HL6G offers great value and performance – perfect for those who need a high-quality load cell for daily weighing needs.
Model | Products Description |
HL6G-200kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
HL6G-300kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
HL6G-500kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
HL6G-750kg-C3 | Aluminium Alloy steel, C3, 2.5m cable, 4 wires. |
Qualification | ||
Load Rating | Kg | 200/ 300/ 500/ 750 |
Precision | C3 | |
Maximum Division | Nmax | 3000 |
Minimum Division | Vmin | Emax/7000 |
Composition Error | (%FS) | ≤±0.020 |
Creep Deformation | (%FS/30min) | ≤±0.0167 |
The influence of temperature on the output sensitivity | (%FS/10℃) | ≤±0.0175 |
The influence of temperature on the zero output | (%FS/10℃) | ≤±0.020 |
Rated Output | (MV/V) | 2.0±0.2 |
Input impedance | (Ω) | 406±6/1065±15 |
Output impedance | (Ω) | 350±3/ 1000±10 |
Insulation Resistance | (MΩ) | ≥5000(50VDC) |
Zero output | (%FS) | 2 |
Temperature compensation range | (℃) | -10~+40 |
Working temperature range | (℃) | -35~+65 |
Recommend excitation voltage | (V) | 5~12(DC) |
Maximum excitation voltage | (V) | 18(DC) |
Safety overload range | (%FS) | 150 |
Limit overload range | (%FS) | 300 |
Position Error | 0.02%/100mm |