Capacity: 5t
The HH8C-SS load cell from HOLI Scale is a high-precision, shear beam load cell. It is designed for use in various industrial weighing applications, where accuracy and reliability are paramount. Made from durable stainless steel, it offers excellent environmental resistance and long-term stability. The HH8C-SS is available in multiple capacities, making it versatile for different load requirements.
Model | Products Description |
HH8C-SS-5000kg-C3 | Stainless steel, Nickel Plated, C3, 5m cable, 4 wires. (6 wires optional) |
Qualification | ||
Load Rating | Kg | 5000 |
Precision | C3 | |
Maximum Division | nmax | 3000 |
Minimum Division | Vmin | Emax/10000 |
Composition Error | %FS | ≤±0.020 |
Creep Deformation | %FS/30min | ≤±0.0016 |
The influence of temperature on the output sensitivity | %FS/10℃ | ≤±0.0011 |
The influence of temperature on the zero output | %FS/10℃ | ≤±0.015 |
Rated Output | MV/V | 3.0±0.003 |
Input impedance | Ω | 350±5 |
Output impedance | Ω | 350±3 |
Insulation Resistance | MΩ | ≥5000(50VDC) |
Zero output | %FS | 1.0 |
Temperature compensation range | ℃ | -10~+40 |
Working temperature range | ℃ | -35~+65 |
Recommend excitation voltage | V | 5~12(DC) |
Maximum excitation voltage | V | 18(DC) |
Safety overload range | %FS | 120 |
Limit overloadrange | %FS | 150 |
Capacity: 5t
The HH8C-SS load cell from HOLI Scale is a high-precision, shear beam load cell. It is designed for use in various industrial weighing applications, where accuracy and reliability are paramount. Made from durable stainless steel, it offers excellent environmental resistance and long-term stability. The HH8C-SS is available in multiple capacities, making it versatile for different load requirements.
Model | Products Description |
HH8C-SS-5000kg-C3 | Stainless steel, Nickel Plated, C3, 5m cable, 4 wires. (6 wires optional) |
Qualification | ||
Load Rating | Kg | 5000 |
Precision | C3 | |
Maximum Division | nmax | 3000 |
Minimum Division | Vmin | Emax/10000 |
Composition Error | %FS | ≤±0.020 |
Creep Deformation | %FS/30min | ≤±0.0016 |
The influence of temperature on the output sensitivity | %FS/10℃ | ≤±0.0011 |
The influence of temperature on the zero output | %FS/10℃ | ≤±0.015 |
Rated Output | MV/V | 3.0±0.003 |
Input impedance | Ω | 350±5 |
Output impedance | Ω | 350±3 |
Insulation Resistance | MΩ | ≥5000(50VDC) |
Zero output | %FS | 1.0 |
Temperature compensation range | ℃ | -10~+40 |
Working temperature range | ℃ | -35~+65 |
Recommend excitation voltage | V | 5~12(DC) |
Maximum excitation voltage | V | 18(DC) |
Safety overload range | %FS | 120 |
Limit overloadrange | %FS | 150 |